We sell three types of filter media: pad filter sheets for plate-and-frame sheet filters, lenticular modules for closed lenticular housings, and cartridges for cartridge housings. All three work best the same way: let the coarser media carry the solids, protect the final filter, clean it promptly after use, store it so nothing grows on it, and check it before it touches wine headed for the bottle.
Keep it chlorine-free. Chlorine is the "C" in TCA. Nothing on this page calls for chlorine, and nothing in your filtration system should see it. See What's Wrong with My Wine?
Which Media Goes Where
| Media | Fits | Best for | Max. differential pressure |
|---|---|---|---|
| FIBRAFIX pad filter sheets | Plate-and-frame sheet filters | Rough clarifying through sterile, plus TX-R sheets to remove TCA/TBA | Exhausted at 1–2.5 bar (15–36 psi), by grade |
| FIBRADISC lenticular modules | Closed lenticular housings | The same sheet grades with no dripping plate-and-frame | 2.4 bar (35 psi); 1.5 bar (21 psi) on sterile grades |
| QXL, QSL, QCR cartridges | Cartridge housings | Prefiltration ahead of a membrane | Change at 35 psid (QXL) |
| ZTEC WB membrane cartridges | Cartridge housings | Final filtration before bottling | Change at 35 psid |
Pad Filter Sheets
How do I install new filter sheets?
Fit the sheets wet. Then rinse them with about 50 liters of clean water per square meter of sheet (about 1.2 gallons per square foot) before use.
When are the sheets used up?
When the differential pressure (inlet minus outlet) climbs past about 1 to 2.5 bar (15 to 36 psi), depending on the grade and the application.
How do I sterilize sheets before a sterile run?
With hot water at 85 °C (185 °F) or with inline steam at 125 °C (257 °F). For chemical sanitizing, the sheets are rated for citric acid up to 10%, peracetic acid at 0.1% and ethanol up to 80%.
Can I reuse filter sheets?
In certain applications the sheets can be regenerated; ask us about yours. Dispose of used sheets according to what was filtered. Untainted sheets can go out with ordinary waste.
How should I store unused sheets?
In the original shrink-wrap and box, in a dry, odorless, well-ventilated room. Use the sheets within 60 months of the manufacture date.
Lenticular Modules
How do I start up a new lenticular module?
Match the adapter to your housing: flat (DOE, double open end) or plug-in (DOR, double O-ring). Rinse with 50 liters of clean water per square meter of filter area before filtering. A 12" 16-lens module has 1.8 m², so that's about 90 liters (24 gallons).
How much pressure can a module take?
Up to 2.4 bar (35 psi) differential, or 1.5 bar (21 psi) for the sterile grades (AF 110 to AF 140). Standard modules run up to 82 °C (180 °F) continuously and 90 °C (194 °F) for short periods. HT modules go to 110 °C (230 °F) continuously and 140 °C (284 °F) for short periods.
Can I backflush a lenticular module?
Only the Plus 2 modules, which are built for it. Backflush them at no more than 0.5 bar (7 psi) at about 25 °C (77 °F). Standard and HT modules aren't back-flushable.
How do I sterilize or sanitize a module?
With hot water, or chemically. The media and polypropylene are rated for citric acid up to 10%, peracetic acid up to 1% and ethanol up to 80%. Check the gasket too: silicone gaskets (the standard) handle citric and peracetic acid well but have only limited resistance to ethanol.
How should I store modules?
Unused modules stay in their sealed plastic bag and box, in a dry, odorless, well-ventilated room. Use them within 60 months of the manufacture date.
Cartridges
A cartridge setup works by reducing the solids load step by step, so that the QXL, QSL and QCR prefilters do the hard work and the ZTEC WB membrane only has to do the last, critical step.
| Cartridge | Role in wine filtration | Common ratings |
|---|---|---|
| QXL | Coarse prefilter with high dirt-holding capacity (pleated depth polypropylene) | 1, 3, 5, 10 µm |
| QSL | Fine depth prefilter that protects the membrane | 0.5 µm |
| QCR | Fine polypropylene prefilter | 0.5, 0.8 µm |
| ZTEC WB | Final PES membrane | 0.2, 0.45, 0.65 µm |
What order do the cartridges go in?
Wine → QXL → QSL and/or QCR → ZTEC WB → bottling. A typical train is QXL 5 µm → QXL 1 µm → QSL 0.5 µm → ZTEC WB 0.45 µm. You don't need every stage every time: choose the combination based on how clean the wine is and the microbial retention you need at the end.
Do I need all the QXL grades?
No. With a heavy solids load you might step down 10 → 5 → 3 → 1 µm, but that's a menu, not a requirement. If the wine is already well clarified by crossflow, DE, pad or lenticular filtration or settling, you can skip most of the coarse QXL steps.
QSL or QCR in front of the membrane?
Both fit the tight prefilter position right ahead of the ZTEC WB. The QSL 0.5 µm is a pleated depth filter with more particle-holding capacity, and it's recommended ahead of the ZTEC WB to help prevent premature membrane clogging. The QCR (0.5 or 0.8 µm) is a fine polypropylene polishing prefilter. Pick based on how loaded the wine is; we can help.
Which ZTEC WB rating: 0.2, 0.45 or 0.65 µm?
All three use the same TECpore PES membrane, with low adsorption of protein, color and flavor, and they're used on red, white and sparkling wine. Published bacterial retention:
- 0.2 µm: LRV ≥7.6 for Pseudomonas aeruginosa
- 0.45 µm: LRV ≥7.52 for Lactobacillus brevis
- 0.65 µm: LRV ≥10.9 for Saccharomyces cerevisiae
Choose the rating based on your winery's microbiological specification and validation requirements, not on the micron rating alone.
How do I set up before filtering?
- Confirm the cartridge sequence and that each one has the right micron rating, length, end fitting and O-ring material. Our standard 30" cartridges are Code 7 (226 O-ring with fin) with silicone seals.
- Lubricate the O-rings with a food-safe wetting agent, and push the cartridges straight in so the seals don't roll or tear.
- Rinse and sanitize the system, then do a final clean-water rinse to remove any chemistry.
- Wet the ZTEC WB membrane completely, then integrity-test it (see below).
- Record the clean differential pressure before wine goes through.
How do I start a filtration run?
Bring it up to flow slowly rather than hitting it with full pump pressure. Let the housing fill completely and vent all the air. Then watch the differential pressure: ΔP = inlet pressure − outlet pressure.
What should I write down?
For each reusable cartridge: starting (clean) ΔP, flow rate, wine and lot, cartridge ID, gallons filtered, ending ΔP, each cleaning and sanitizing cycle, and the membrane's integrity-test result. That builds a life history for each reusable cartridge.
When do I change a cartridge?
ZTEC WB and QXL cartridges are both rated for change-out at 35 psid (2.4 bar). Watch the trend, not just the final number. A steady climb means solids are building up in or on the cartridge. If pressure climbs unusually fast, review the upstream filtration before pushing the membrane harder. ZTEC WB limits: 80 psid at 70 °F, 40 psid at 160 °F, 40 psid in reverse at 70 °F, and 176 °F (80 °C) maximum at 20 psid.
How do I clean and regenerate cartridges after filtering?
Do it right away, and always flush in the forward direction:
- 1. Ambient rinse: prefiltered water, 5–10 minutes at more than 5 psid. This removes soluble wine residue before heat can bake proteins and glucans onto the media.
- 2. Hot-water regeneration: prefiltered water at 125–180 °F (50–80 °C), 5–30 psid, for 15–20 minutes. Never above 180 °F (80 °C).
- 3. Heavily loaded cartridges only: an extended soak, or a 30–60 minute forward flush, with peracetic acid (100–400 ppm), hydrogen peroxide (1–10%) or citric acid (1–5%).
- 4. Cold rinse: prefiltered water, to cool the cartridge and remove any chemistry.
Filter the rinse water itself to a rating at least as fine as the cartridge being cleaned. Rust, sand and grit in process water can plug a cartridge for good.
Can I backflush the ZTEC WB membrane?
Not as routine. Reverse flow puts much more stress on a membrane than forward flow, especially with hot water. Make forward regeneration the default for ZTEC WB, and treat reverse flow as a controlled regeneration procedure, not a normal routine.
What can I sanitize cartridges with?
Chlorine-free options:
- Peracetic acid, 100–200 ppm
- Hydrogen peroxide, 10%
- Citric acid, 1%
- 70% ethanol or isopropyl alcohol
Soak 30–60 minutes at about 80 °F (27 °C), then rinse thoroughly with clean water. Keep this routine sanitizing procedure separate from the stronger regeneration procedure above.
Can I use hot water or steam?
Hot water: 180 °F (80 °C) for 30 minutes, keeping ΔP under 3 psid (0.21 bar) across the cartridge. Steam: 250 °F (121 °C) for 30 minutes, with no more than 5 psid (0.34 bar) differential. Steaming requires a cartridge with the right end-cap insert. ZTEC WB cartridges are rated for at least 50 thirty-minute steam or autoclave cycles at 275 °F (135 °C).
How do I store cartridges between uses?
Reusing within a few days or weeks: store them wet, fully submerged in a sanitizing solution that won't let anything grow, such as citric acid, alcohol or hydrogen peroxide.
Longer than a few weeks: dry them completely (air or nitrogen above the bubble-point pressure speeds it up), seal them in a clean bag, and keep them protected until needed.
Never leave a cartridge damp: neither properly stored wet nor completely dry. That's where microbes grow.
How do I integrity-test a ZTEC WB membrane?
Test it before production and after any storage or regeneration, and make it part of your written bottling procedure. Don't judge a membrane by its flow rate. Minimum bubble points for water-wet ZTEC WB cartridges:
- 0.2 µm: ≥26 psig
- 0.45 µm: ≥20 psig
- 0.65 µm: ≥17 psig
Maximum diffusive air flow is 35 cc/min per 10" element at the test pressure. For a pressure-hold test, the allowable pressure decay depends on your housing volume; ask us for the calculation.
What's the short version?
- Before use: inspect → install → rinse → sanitize → wet → integrity-test the ZTEC WB → record clean ΔP.
- Filtering: start slowly → vent the housing → watch ΔP → record gallons.
- After use: ambient forward rinse → hot forward rinse → chemical regeneration only if needed → clean-water rinse.
- Reusing soon: store fully submerged in sanitizer.
- Storing longer: dry completely → clean bag → sealed.
- Before the next bottling: rinse → sanitize → wet → integrity-test → back to work.
Questions about your setup? Tell us your filter or housing make and size and what you're filtering, and we'll match the media. See our filter media or call Joe at phone.